Table 2.

The Comparison of Equivalent Stress (von Mises) distribution in the different bones of intact ankle joint between the Ozen et al.6 FE model and the present FE model.

Bone Peak von Mises stress
Ozen et al.6 Present study
Tibia 5.550 5.863
Fibula 1.267 1.297
Talus 2.068 2.384
Calcaneous 3.464 4.014