Table 2.
Application scope.
Entry[a] | R | T [°C] | t [h] | Conv.[b] [%] | Yield[c] [%] | TON[d] | TOF[d] [h−1] |
---|---|---|---|---|---|---|---|
1 | Ph | 60 | 8 | >95 | 94 | 1880 | 235 |
2 | Ph | 25 | 8 | 25 | 24 | 480 | 60 |
3 | 4‐Cl‐C6H4 | 60 | 8 | >98 | 96 | 1920 | 240 |
4 | 4‐F‐C6H4 | 60 | 8 | >98 | 98 | 1960 | 245 |
5 | PhOCH2 | 60 | 8 | >95 | 94 | 1880 | 235 |
6 | Ph2CHOCH2 | 60 | 8 | 71 | 70 | 1400 | 175 |
7 | ClCH2 | 60 | 8 | 89 | 88 | 1760 | 220 |
8 | vinyl | 60 | 8 | >98 | 93 | 1860 | 232 |
9 | but‐3‐enyl | 60 | 8 | >98 | 98 | 1960 | 245 |
10 | but‐3‐enyl | 25 | 20 | >98 | 98 | 1960 | 98 |
11 | Me | 25 | 8 | 57 | 55 | 1100 | 137 |
12 | Me | 25 | 20 | >95 | 88 | 1760 | 88 |
[a] 4 mmol scale (neat); [b] judged by 1H NMR of the reaction mixture; [c] isolated yield after filtration over a short plug of silica; [d] based on 1 a. TON=turnover number; TOF=turnover frequency.