Table 2.
The mean absolute difference between intraoperative electrocochleography (ECochG) thresholds and postoperative behavioral thresholds at 125, 250, and 500 Hz frequencies are shown in the overall cohort.
| Frequency (Hz) | Δ Intraop ECochG and postop behavioral thresholds, overall mean in dB HL (range) | Δ Intraop ECochG and postop behavioral thresholds, ST Insertion mean in dB HL (range) | Δ Intraop ECochG and postop behavioral thresholds, SV insertion mean in dB HL (range) | p-value |
|---|---|---|---|---|
| 125 | 29 (1–69) | 16 (1–28) | 46 (33–69) | 0.001 |
| 250 | 24 (2–55) | 13 (2–29) | 41 (30–55) | 0.001 |
| 500 | 19 (2–40) | 12 (2–38) | 22 (6–35) | 0.310 |
Differences are also depicted according to scalar location of the electrode array; the P value represents the comparison between scala tympani (ST) insertions and scala vestibuli (SV) insertions. Means and ranges are reported. Bonferroni correction is applied for multiple comparisons, with p < 0.017 indicative of statistical significance.