Table 1.

Degree of bioburden on orthopaedic operating room surfaces measured in relative light units (RLUs)

OR surface Mean SD Minimum Maximum
Inside sterilized pan 9.2 5.5 5 20
OR preparation table (predrape) 1054 387.5 403 1562
OR preparation table (postdrape) 8.3 3.4 5 14
OR light handles 647.8 903.7 84 2456
Bovie machine buttons 1264.5 638.8 366 2278
Supply closet countertops 281.7 236.7 83 677
Inside Bair Hugger™ hose 212.5 155.7 72 423
Bair Hugger™ buttons 1340.8 1064.1 278 2880
Right side of OR table headboard 2539 5635.8 142 14,042
Tourniquet machine buttons 1666.5 2144.9 453 5994
Clark-socket attachment 1135.7 705.3 273 2159
Patient positioner 1201.7 1144.9 296 3428
Computer keyboard 1810.8 929.6 297 2588

OR = operating room.