Table 3.

LV segmentation failures in the 962 patients whose image datasets were processed using (left) the conventional algorithm and (right) the “same-patient processing” approach, broken down by how many of the six datasets associated with each patient were affected by failure.

Failures
(conventional processing)
Failures
(“same-patient” approach)
1 dataset 98/962 (10.2%) 5/962 (0.5%)
2 datasets 21/962 (2.2%) 3/962 (0.3%)
3 datasets 13/962 (1.3%) 5/962 (0.5%)
4 datasets 7/962 (0.7%) 1/962 (0.1%)
5 datasets 0/962 (0%) 0/962 (0%)
6 datasets (all) 2/962 (0.2%) 2/962 (0.2%)
At least 1 dataset 141/962 (14.7%) 16/962 (1.7%)