Skip to main content
. 2014 Mar 27;7(4):2440–2458. doi: 10.3390/ma7042440

Table 2.

Central Composite Design (CCD) experimental design and results of the response surface.

Run Factor A, Temperature (°C) Factor B, pressure (bar) Factor C, Hydrogen (bar) Response, Y, Polymer conversion (%) (Experimental result)
1 70 20 10 3.10
2 70 20 2 5.20
3 75 20 6 4.53
4 80 20 10 3.32
5 80 20 2 5.40
6 75 25 10 3.86
7 70 25 6 5.00
8 75 25 6 5.20
9 75 25 6 5.20
10 75 25 6 5.21
11 75 25 6 5.20
12 75 25 6 5.21
13 75 25 6 5.19
14 75 25 2 5.82
15 80 25 6 5.10
16 70 30 2 5.38
17 70 30 10 3.10
18 75 30 6 5.00
19 80 30 2 5.68
20 80 30 10 3.57