Table 2.
Sample Number | Thermal Conductivity Coefficient (W/mK) (Test temperature 22–30 °C) | Density (kg/m3) | Specific Heat Capacity (J/kg·K) (Test Temperature 5 °C/35 °C) | Enthalpy (J/kg) |
---|---|---|---|---|
Cement paste | 0.91 | 2230 | 1033/1033 | / |
Cement paste with KO-CPCM | 0.77 | 1980 | 1180/1228 | 7842 |
Cement paste with GGBS-CPCM | 0.82 | 2050 | 1061/1132 | 4038 |