Table 2. Percentiles of the distributions of lumen areas and distance between the lumen contours obtained with the automatic and manual segmentation methods.
25th percentile | 50th percentile | 75th percentile | |
---|---|---|---|
Lumen area [mm2] | |||
Auto | 5.836 | 8.608 | 9.078 |
R1 | 5.895 | 8.542 | 9.032 |
R2 | 5.875 | 8.546 | 9.074 |
Lumen contours distance [μm] | |||
Auto vs. R1 | 0.0 | 13.0 | 26.0 |
Auto vs. R2 | 13.0 | 13.0 | 39.0 |
R1 vs. R2 | 0.0 | 13.0 | 26.0 |
Auto—automatic detection algorithm; R1 –image reader 1; R2 –image reader 2