Skip to main content
. 2016 Oct 13;9(10):829. doi: 10.3390/ma9100829

Table 3.

Results of the direct tensile test.

Specimen At First Cracking At Ultimate Stress
Stress (MPa) CMOD (mm) Stress (MPa) CMOD (mm)
Method A-1 6.79 0.007 7.34 0.249
Method A-2 5.56 0.007 7.73 0.215
Method A-3 7.70 0.008 7.70 0.008
Average 6.68 0.007 7.59 0.157
St. dev. 1.07 0.001 0.217 0.130
Method B-1 8.69 0.008 15.10 0.601
Method B-2 8.08 0.008 14.58 0.109
Method B-3 5.88 0.006 15.09 0.397
Average 7.55 0.007 14.92 0.369
St. dev. 1.48 0.001 0.297 0.247