Rate constant determined from slope of the plots in Figure 6a,b at each operation period.

Condition Rate Constant (k)[Contact Time Duration]
Reactor A (Water + E. coli + Sun) 0.0050[2–8 h]
Reactor B (Water + E. coli + TiO2 + Sun) 0.0061[2–8 h]
Reactor C (Water + E. coli + TiO2 + UV) 0.0071[2–8 h]
k1[0–2 h] k2[2–4 h] k3[4–8 h]
Reactor 1 (TiO2 film area:water volume = 1:2.62) 0.0691 0.0053[2–8 h]
Reactor 2 (TiO2 film area:water volume = 1:5.24) 0.0138 0.0490 0.0110
Reactor 3 (TiO2 film area:water volume = 1:7.86) 0.0096 0.0458 0.0072