Skip to main content
. 2016 Jun 20;9(6):491. doi: 10.3390/ma9060491

Table 4.

Descriptive statistics of modifications of the CieLab-System parameters (baseline: veneering material) of all tested material assemblies, regardless of the veneering thickness.

VITA EasyShade Lab-Values VITA Mark II/A2 VITA Enamic/A3.5 LAVA Ultimate/B2 IPS e.max CAD/B3
PEEK
CieLab-System L mean (SD) −12.1 (5.2) −11.2 (5.9) −13.4 (6.6) −10.3 (5.2)
a mean (SD) −0.8 (0.3) −1.4 (0.1) −2.3 (0.5) −1.9 (0.1)
b mean (SD) −7.4 (1.8) −7.6 (1.6) −11.7 (1.5) −8.4 (2.1)
E mean (SD) 14.3 (5.1) 13.8 (5.8) 18.4 (5.4) 13.6 (5.3)
ZrO2
CieLab-System L mean (SD) −10.5 (4.8) −10.1 (5.4) −12.1 (6.1) −9.2 (4.7)
a mean (SD) −1.1 (0.5) −0.5 (0.3) −1.1 (0.1) −1.1 (0.1)
b mean (SD) −5.4 (1.6) −6.0 (0.9) −8.4 (1.5) −6.8 (1.5)
E mean (SD) 12.1 (4.6) 11.9 (5.0) 15.0 (5.8) 11.7 (4.6)
CoCrMo
CieLab-System L mean (SD) −10.4 (4.7) −9.8 (5.4) −11.7 (6.1) −8.9 (4.6)
a mean (SD) −0.3 (0.3) −0.8 (0.1) −1.4 (0.1) −1.3 (0.1)
b mean (SD) −5.5 (1.6) −5.9 (1.1) −8.3 (1.8) −6.7 (1.6)
E mean (SD) 11.9 (4.5) 11.6 (5.1) 14.5 (6.0) 11.3 (4.6)
TiO2
CieLab-System L mean (SD) −4.8 (2.3) −4.5 (2.5) −5.3 (2.9) −4.1 (2.1)
a mean (SD) −0.5 (0.5) −0.7 (0.4) −1.6 (0.6) −1.1 (0.5)
b mean (SD) −4.2 (1.8) −4.1 (1.6) −5.3 (2.2) −4.0 (1.6)
E mean (SD) 6.5 (2.9) 6.2 (2.9) 7.7 (3.6) 5.8 (2.7)