Table 1.
Sample ID | LOI (%) | t 1 (s) | Dripping | UL-94 Rating |
---|---|---|---|---|
EP-0 | 24.1 | >180 | Yes | No Rating |
EP-0.5 | 28.2 | 36 | No | No Rating |
EP-1 | 28.3 | 32 | No | No Rating |
EP-1.5 | 28.8 | 25 | No | V-1 |
EP-2 | 29.3 | 8 | No | V-0 |
EP-2.5 | 29.5 | 5 | No | V-0 |
1 t: total time of the first and second burning times for five specimens in UL-94 test; LOI = limiting oxygen index.