Skip to main content
. 2016 Nov 8;9(11):905. doi: 10.3390/ma9110905

Table 2.

Samples used for each technique and exposure media.

Technique Exposure Medium Type of Sample Exposure Time Samples Tested Standard
Impedance spectroscopy 15 wt % Na2SO4 Disks 10 cm diameter and 2 cm thickness Up to 120 days 5 n/a
Distilled water Disks 10 cm diameter and 1 cm thickness Up to 90 days 5 n/a
Electrical resistivity 15 wt % Na2SO4 Cylinders 30 cm height and 7.5 cm diameter Up to 120 days 4 UNE 83988-2
Distilled water Cylinders 30 cm height and 15 cm diameter Up to 90 days 4 UNE 83988-2
Mercury intrusion porosimetry 15 wt % Na2SO4 Pieces of disks 10 cm diameter and 2 cm thickness 28, 60, 90 and 120 days 2 n/a
Distilled water Pieces of disks 10 cm diameter and 1 cm thickness 2, 28 and 90 days 2 n/a
Compressive strength 15 wt % Na2SO4 Prisms 4 cm × 4 cm × 16 cm 28 days 3 UNE-EN 196-1
Distilled water Prisms 4 cm × 4 cm × 16 cm 28 days 3 UNE-EN 196-1