Skip to main content
. 2017 Jun 6;7:2877. doi: 10.1038/s41598-017-03296-6

Table 2.

Receiver operating characteristic analysis: area under the curves and optimal cut-off values.

Parameter NSCLC AC SCC
AUC(95%CI) Cut-off value P AUC(95%CI) Cut-off Value P AUC(95%CI) Cut-off Value P
SUVmax 0.95(0.91–0.98) >1.4 0.002 0.86(0.78–0.92) >1.4 0.02 0.98(0.91–1.0) >1.3 0.14
SUVmean 0.94(0.90–0.97) >1.2 0.008 0.83(0.75–0.90) >1.1 0.05 0.97(0.89–1.0) >1 0.29
SUVLN/PT 0.89(0.83–0.93) >0.3 0.71(0.61–0.79) >0.3 0.95(0.86–0.99) >0.3
SUVLN/MBP 0.92(0.87–0.96) >1.5 0.24 0.82(0.73–0.89) >0.9 0.40 0.98(0.91–1.0) >1.5 0.14
SUVLN/M 0.97(0.94–0.99) >2.4 0.01 0.94(0.88–0.98) >2.4 0.06 0.98(0.91–1.0) >2.6 0.14

CI, confidence interval; SUV, standardized uptake value; LN, lymph node; MBPS, mediastinal blood pool; PT, primary tumor; M, muscle; P, P value.