Skip to main content
. 2017 Mar 2;28(6):1943–1950. doi: 10.1681/ASN.2016060670

Table 6.

Cox regression analysis (univariate) assessment of biomarkers for prediction of allograft loss due to CPR versus other causes

Serum Biomarker RR (95% CI) P Value β/SEM
Univariate
 IgA, mg/ml NS (0.12)
 Norm Gd-IgA1, % NS
 Total Gd-IgA1,U/ml NS
 IgG, mg/ml NS
 Norm IgG-autoAb, OD NS
 Total IgG-autoAb, U/ml NS
 Norm IgA-autoAb, OD 2.34 (0.94 to 5.84) NS (0.07) +1.82
 Total IgA-autoAb, U/ml 1.41 (1.10 to 1.81) <0.01 +2.67

Thirty-four recipients lost their allograft: 17 due to CPR and 17 due to other causes. β/SEM indicates the weight of the covariate with increasing (+) and decreasing (−) the risk. Gd-IgA1 is the major autoantigen. Norm, normalized.