Skip to main content
. 2017 Jan 20;55(3):201–209. doi: 10.2486/indhealth.2016-0047

Table 1. Overview of the selected studies.

Author(s) Year Research origin Category Intervention
Bates and Schneider25) 2008 United Arab Emirates Administrative
Environmental engineering
Fluid intake, Self-pacing
TWL monitoring
Bates et al.27) 2010 United Arab Emirates Administrative Fluid intake
Chan and Yang34) 2016 Hong Kong SAR Administrative PeSI monitoring
Chan et al.30) 2012a Hong Kong SAR Administrative Optimal recovery time
Chan et al.31) 2012b Hong Kong SAR Administrative Optimal recovery time
Chan et al.42) 2012 Hong Kong SAR Environmental engineering TWL monitoring
Chan et al. 2013 Hong Kong SAR Personal engineering Hybrid cooling vest; Cooling vest with frozen gel packs
Chan et al.45) 2013 Hong Kong SAR Personal engineering Hybrid cooling vest; Cooling vest with frozen gel packs
Chan et al.46) 2015 Hong Kong SAR Personal engineering Hybrid cooling vest; Cooling vest with frozen gel packs
Chan et al.47) 2016 Hong Kong SAR Personal engineering Hybrid cooling vest
Chan et al.48) 2016 Hong Kong SAR Personal engineering Hybrid cooling vest
Chan et al.49) 2016 Hong Kong SAR Personal engineering Hybrid cooling vest; Cooling vest with frozen gel packs
Chan et al.50) 2016 Hong Kong SAR Personal engineering Hybrid cooling vest
Chan et al.51) 2015 Hong Kong SAR Personal engineering Work unifrom
Chan et al.52) 2016 Hong Kong SAR Personal engineering Work unifrom
Chan et al.53) 2016 Hong Kong SAR Personal engineering Work unifrom
Dehghan et al.41) 2012 Iran Environmental engineering WBGT monitoring
Farshad et al.40) 2014 Iran Environmental engineering TWL monitoring
Heus and Kistemaker44) 1998 n.a. Personal engineering Work unifrom
Jia et al.37) 2016 Hong Kong SAR Administrative Socio-ergonomic model
Miller and Bates28) 2007a Australia Administrative Fluid intake
Miller and Bates39) 2007 Australia Environmental engineering TWL monitoring
Miller et al.4) 2011 United Arab Emirates Administrative Self-pacing
Montazer et al.29) 2013 Iran Administrative Fluid intake
Rowlinson and Jia9) 2014 Hong Kong SAR Administrative Optimized work-rest regimen
Rowlinson and Jia38) 2015 Hong Kong SAR Administrative Proactive and reactive behavioural intervention
Pérez-Alonso et al.1) 2011 Spain Administrative
Environmental engineering
Optimized work-rest regimes
ESI monitoring
Yabuki et al.35) 2013 Japan Administrative Heatstroke prevention system
Yang and Chan33) 2015 Hong Kong SAR Administrative PeSI monitoring
Yang and Chan55) 2016 Hong Kong SAR Personal engineering Work uniform
Yi and Chan8) 2013 Hong Kong SAR Administrative Optimized work-rest schedule
Yi and Chan26) 2014 Hong Kong SAR Administrative
Environmental engineering
Heat tolerance time
WBGT monitoring
Yi and Chan32) 2014 Hong Kong SAR Administrative Optimal work pattern
Yi et al.36) 2016 Hong Kong SAR Administrative Early-warning system
Yi et al.54) 2016 Hong Kong SAR Personal engineering Work unifrom

Abbreviation: ESI: environmental stress index; PeSI: perceptual strain index; TWL: thermal work limit; WBGT: wet bulb globe temperature