Table 2. 2011 Noise levels.

Area/Operation LAeq 1 min
dB(A)
period before eight h
standard exceeded*
(hrs:min)
Points where/when measurements taken
Grinding room (3)
Grinder 88 4:00 During grinding of orthotic.
Grinder 84 10:00 Whilst no grinding was being undertaken but extraction was on.
Grinder 88 4:00 Grinding orthotic
Laminating Room (4)
Right hand extraction hood 93 1:16 30 cm from hood. Both left and right hood slide gate dampers open.
Right hand extraction hood 89 3:12 30 cm from hood. Both left side gate damper closed and right slide damper open.
Left hand extraction hood 93 1:16 30 cm from hood. Both left and right hood slide gate dampers open
Left hand extraction hood 96 0:38 30 cm from hood. Both left side gate damper closed and right slide damper open

*without hearing protection