Table 3. 2013 Noise levels.
| Area/Operation | LAeq 1 min dB(A) |
period before eight h standard exceeded* (hrs:min) |
Points where/when measurements taken |
|---|---|---|---|
| Grinding Room (3) | |||
| Grinder | 95 | 0:47 | Fan speed 100% with all other outlets blocked off |
| Grinder | 92 | 1:35 | Fan speed 100% with one other outlet open |
| Grinder | 89 | 3:11 | Fan speed 100% with all other outlet open |
| Grinder | 83 | >12 | Fan speed 60% and all other outlets closed |
| Chipping plaster leg mould with air chisel to recover mandrel |
103 | 0:07 | At staff member’s ear |
| Chipping plaster leg mould with air chisel to recover mandrel |
82 | >12 | Outside Grinding Room during chisel use. |
| Laminating Room (4) | |||
| Laminating Room | 74 | >12 | |
| Gluing Bench (1) | |||
| Gluing Bench | 78 | >12 | Rear extraction only on. |
| Gluing Bench | 75 | >12 | Both rear extraction and flexible arm extraction on. |
*without hearing protection