Skip to main content
. 2017 Feb 7;55(3):285–292. doi: 10.2486/indhealth.2016-0089

Table 5. 2013 Volatile Organic Compound results.

Operator Process Total time
worn/min
exposed
TWA (ppm) TWA Exposure Standards (maximum allowed)
Technician Sealing orthotic casts using methylated spirits
Using 3M Super 77 Spray Adhesive
Mixing and applying Eco-Lam Resin and sealing resin
277 Pentanes=16.25 ppm
Methyl Methacrylate=ND
Isopropyl Alcohol=3.94 ppm
Toluene=ND (50 ppm)
Xylenes=ND (80 ppm)
MEK=ND (150 ppm)
Acetone=0.58 (500 ppm)
600 ppm
50 ppm
400 ppm
50 ppm
80 ppm
150 ppm
500 ppm
Prosthetist Plaster Work
Office work
No gluing but working adjacent to gluing bench
387 Methyl Methacrylate=ND
Ethyl Alcohol=4.35 ppm
Toluene=ND
Xylenes=ND
MEK=ND
Acetone=ND
50 ppm
1,000 ppm
50 ppm
80 ppm
150 ppm
500 ppm
Prosthetist Plaster Work
Office work
Gluing orthotic using Foss Adhesive and solvent
396 Methyl Methacrylate=ND
Ethyl Alcohol=3.38 ppm
Toluene=ND
Xylenes=ND
MEK=ND
Acetone=ND
50 ppm
1,000 ppm
50 ppm
80 ppm
150 ppm
500 ppm

ND=Not Detected

No other specific VOC’s were detected in any of the samples