Skip to main content
. 2017 Jun 8;7:3077. doi: 10.1038/s41598-017-03228-4

Figure 3.

Figure 3

Twisting test of magnetic microwire. (a) The microwire is assembled on the two sample holders of iTRo with gauge length approximate 1400 μm. (b) and (c) gives SEM images at twisting angle 90° and 300° respectively. (d) Microwire is broken at twisting angle 565°. (e) SEM image of the fracture plane, indicating it’s a typical ductile failure caused by shear stress.