Skip to main content
. 2017 May 10;17(5):1082. doi: 10.3390/s17051082

Table 6.

Run-time and Overall Accuracy of the Classifiers (* processing time for fusion feature vector of data from microphone and piezoelectric).

Classifier Mean Run-Time for Each Segmented Database Overall Accuracy (%) Overall Accuracy Median (%)
Feature Extraction Training Classification
ANN 81 20.8 0.9 97.5 83.8
SVM 81 24.8 0.6 95.1 86.9
HSVM 325 * 156.9 * 2.4 * 96.6 91.8