Skip to main content
. 2017 May 21;595(12):3867–3889. doi: 10.1113/JP273879

Table 3.

Sensitivity analysis for the SHAM and AB models

PCa DCa RT50 T peak
Parameter Description SHAM AB SHAM AB SHAM AB SHAM AB
g SERCA Maximum pump rate of SERCA −0.301 0.138 −1.217 −1.588 −1.515 −1.493 0 0
K SERCA Half saturation of SERCA 0.351 −0.029 1.246 1.173 0 0 0 0
g CaB Conductance of background Ca2+ 0.050 0.024 0.0014 0.0357 0 0 0 0
g t Conductance of transient outward K+ −3.355 0.280 −3.563 0.1959 −4.545 0 −3.846 0
g K1 Conductance inward rectifying K+ −0.304 0.080 −0.352 −0.0211 0 0 0 0
g Na Conductance of inward Na+ −0.157 −0.027 8.7 × 10–5 −0.098 0 0 0 0
g ss Conductance of steady state K+ −0.664 0.004 −0.744 −0.003 −1.515 0 0 0
V L Potential when half LCC channels are open −0.664 −0.087 3.242 −0.217 4.546 0 3.846 0
K L Concentration at LCC inactivation 3.111 0.481 1.061 1.299 1.515 1.492 0 0
J L Permeability of a single LCC 5.706 0.342 5.777 −0.132 7.576 −1.492 7.692 0
g NCX Pump rate of NCX −0.151 −0.335 −0.169 −0.302 0 0 0 0

Sensitivity values Si,j, where i are the phenotypes and j are the tested parameters. In the case of the sensitivity being positive, an increase in the parameter will lead to an increase in the output. In the case of the sensitivity being negative, an increase in the parameter will lead to a decrease in the output.