Skip to main content
. 2017 May 21;595(12):3867–3889. doi: 10.1113/JP273879

Table 4.

Summary of all the fitted parameters in the SHAM model

Parameter Unit Definition
g NCX =0.0234×103
μm 3 ms–1 Pump rate of NCX
g PMCa =0.005×103
μm 3 ms–1 Maximum pump rate of sarcolemmal pump
K PMCa =0.35×103
mm Half saturation of sarcolemmal pump
g SERCA 1=0.235×103
μm 3 ms–1 Maximum pump rate of SERCA at 1 Hz
K SERCA 1=0.497×103
mm Half saturation of SERCA at 1 Hz
g SERCA 6=0.51×103
μm 3 ms–1 Maximum pump rate of SERCA at 6 Hz
K SERCA 6=0.69×103
mm Half saturation of SERCA at 6 Hz
JL=8×104
μm 3 ms–1 Permeability of single LCC
KL=0.00038
mm Concentration at inactivation LCC
VL=9
mV Potential when half LCC open
δ VL =7
mV Width of opening potential
φL=11.5
Unitless Proportion of time closed in open mode LCC
τL=1550
ms Inactivation time
gD=0.1
μm 3 ms–1 Permeability of the leak current from the dyadic space
g SRL =1×106
ms–1 Rate of leak from the SR to the cytosol
g CaB =2×108
mm mV–1 ms–1 Background Ca2+ current rate
gt=2×105
mS Permeability of the transient outward potassium current
g ss =1.3×105
mS Permeability of the steady state potassium current
gK1=4×105
mS Permeability of the inward rectifying current
g Na =0.0007
mS Permeability of the inward sodium current