Table 3.

Border positioning errors (mm) achieved by hierarchical classifier, gradient cost and single stage RF classifier.

NAF+RF (Proposed) Gradient p-value RF only
Femur signed 0.03±0.19 −0.31±0.28 ≪ 0.001 −0.06±0.18
Femur unsigned 0.55±0.11 0.68±0.20 ≪ 0.001 0.56±0.11
Tibia signed 0.10±0.17 0.08±0.35 0.62 0.16±0.24
Tibia unsigned 0.61±0.14 0.81±0.18 ≪ 0.001 0.65±0.17