Skip to main content
. 2017 Jun 6;12:4285–4297. doi: 10.2147/IJN.S131163

Figure 7.

Figure 7

(A) Noncumulative Ag+ release from Ag-coating of titanium disks in the culture at 37°C as a function of immersion time (μg/L/h; n=3). (B) Average cumulative silver released from Ag-coating titanium disks in the culture at 37°C as a function of immersion time (μg/L). All the data expressed as mean ± standard deviation (n=3). (C) Mean release rate of Ag+ from Ag-containing titanium disks (n=3).