Skip to main content
. 2017 Apr 19;24(Pt 3):615–621. doi: 10.1107/S1600577517005422

Table 2. Elliptical parameters of the two mechanically bent X-ray mirror systems.

  Mirror 1 (C-line) Mirror 2 (E-line)
Source to mirror p (m) 57.9 54.38
Mirror to focus q (m) 5.86, 6.16, 6.96 4.599, 4.899, 5.699
Angle of incidence θ (mrad) 3 3