Table 2. Elliptical parameters of the two mechanically bent X-ray mirror systems.
| Mirror 1 (C-line) | Mirror 2 (E-line) | |
|---|---|---|
| Source to mirror p (m) | 57.9 | 54.38 |
| Mirror to focus q (m) | 5.86, 6.16, 6.96 | 4.599, 4.899, 5.699 |
| Angle of incidence θ (mrad) | 3 | 3 |
| Mirror 1 (C-line) | Mirror 2 (E-line) | |
|---|---|---|
| Source to mirror p (m) | 57.9 | 54.38 |
| Mirror to focus q (m) | 5.86, 6.16, 6.96 | 4.599, 4.899, 5.699 |
| Angle of incidence θ (mrad) | 3 | 3 |