TABLE 5.
Estimated Sensitivities and Specificities (Including 95% CIs and Thresholds) for Apparent Diffusion Coefficient (ADC) Value, Forward Volume Transfer Constant (Ktrans) Value, and the Combination of Both Parameters in Differentiating Between Different Gleason Scores (GSs)
| GS, Variable | Sensitivity (95% CI) | Specificity (95% CI) | Threshold |
|---|---|---|---|
|
| |||
| 3 + 3 vs 3 + 4 or higher | |||
| Median ADC value | 0.547 (0.329–0.841) | 0.800 (0.500–0.956) | 0.888 × 10−3 mm2/s |
| Median Ktrans value | 0.445 (0.382–0.864) | 0.800 (0.364–0.907) | 0.248 min−1 |
| 3 + 4 or lower vs 4 + 3 or higher | |||
| Median ADC value | 0.488 (0.406–0.960) | 0.778 (0.331–0.874) | 0.792 × 10−3 mm2/s |
| Median Ktrans value | 0.780 (0.652–0.920) | 0.627 (0.548–0.723) | 0.229 min−1 |
| Both | 0.902 (0.500–0.963) | 0.492 (0.442–0.890) | 4591.90 × ADC − 6.76 × Ktrans = 2.70 |
| 4 + 3 or lower vs 4 + 4 or higher | |||
| Median ADC value | 0.714 (0.546–1.000) | 0.634 (0.298–0.852) | 0.84 × 10−3 mm2/s |
| Median Ktrans value | 0.857 (0.613–1.000) | 0.660 (0.526–0.913) | 0.252 min−1 |
| Both | 0.929 (0.667–1.000) | 0.647 (0.598–0.957) | 7703.71 × ADC − 10.45 × Ktrans = 3.70 |