Table 5.
Entry | Complex | λ PL (nm) | Φ PL (%) | L max (cd m−2) | CE (cd A−1) | EQE (%) | PE (lm W−1) | t 1/2 (h) | CIE (x) | CIE (y) | λ EL (nm) | References |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 20 | 588 | 9 | 395 | 13.2 | 6.1 | 0.53 | 0.47 | 588 | [46] | ||
2 | 21 | 595 | 7 | 284 | 14.7 | 6.1 | 15.3 | 660 | [62] | |||
3 | 22 | 605 | 23 | 16.45 | 9.16 | 26.91 | 0.51 | 0.48 | 580 | [53, 63] | ||
4 | 23 | 568 | 59 | 105 | 5.5 | 18.7 | 566 | [47] | ||||
5 | 24 | 570 | 47 | 79 | 4.0 | 17.1 | 577 | [67] | ||||
6 | 25 | 595 | 3 | 290 | 9.7 | 4.0 | 10.1 | 3000 | [61] | |||
7 | 26 | 595 | 3 | 70 | 3.1 | 1.1 | 3.3 | 1300 | [68] | |||
8 | 27 | 574 | 2 | 105 | 4.0 | 2000 | 0.49 | 0.50 | [69] | |||
9 | 28 | 623 | 26 | 130 | 0.3 | 0.46 | 110 | 0.55 | 0.44 | 594 | [70] | |
10 | 29 | 593 | 5 | 183 | 8.2 | 3.4 | 8.6 | 950 | [62] | |||
11 | 29 | 650 | 3.6 | >4000 | [71] | |||||||
12 | 30 | 583 | 43 | 684 | 6.5 | 2000 | 0.54 | 0.44 | 589 | [72] | ||
13 | 31 | 600 | 13 | 1024 | 3.5 | 2800 | [14] | |||||
14 | 32 | 611 | 4 | 676 | 2.2 | 1204 | [14] | |||||
15 | 33 | 645 | 2 | 261 | 0.7 | >2800 | [14] |
λ PL is the solution-state emission maximum in MeCN, Φ PL is the photoluminescence quantum yield in deaerated solution, L max is the maximum luminance observed from device, CE is the current efficiency, PE is the power conversion efficiency, t 1/2 is the time taken for the device luminance to fall to half the maximum value, λ EL is the electroluminescence emission maximum