Table 6.
Entry | Complex | λ PL (nm) | Φ PL (%) | L max (cd m−2) | CE (cd A−1) | EQE (%) | PE (lm W−1) | t 1/2 (h) | CIE (x) | CIE (y) | λ EL (nm) | References |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 34 | 624 | 0.68 | 7500 | 7.4 | 10 | 0.67 | 0.32 | 635 | [33] | ||
2 | 35 | 627 | 3 | 70 | 1.6 | 2.6 | 0.66 | 0.33 | 650 | [46] | ||
3 | 36 | 556 | 24 | 154 | 13.1 | 9.51 | 8.17 | 0.59 | 0.40 | 624 | [24] | |
4 | 37 | 573 | 58 | 217 | 6.29 | 2.74 | 9.83 | 0.50 | 0.41 | 616 | [24] | |
5 | 38 | 619 | 55 | 2.5 | 3.27 | 2.56 | 0.65 | 0.34 | 644 | [74] | ||
6 | 39 | 666 | 2.6 | 14 | 0.08 | 6.3 | 0.68 | 0.33 | 666 | [75] | ||
7 | 40 | 608 | 6 | 626 | 2.7 | 1.67 | 25 | 0.59 | 0.41 | 607 | [76] | |
8 | 41 | 687 | 2 | ca. 35 | 0.83 | 0.87 | 0.52 | 0.71 | 0.28 | 630 | [77] | |
9 | 42 | 687 | 1 | ca. 35 | 0.68 | 0.71 | 37 | 0.69 | 0.29 | 660 | [77] |
λ PL is the solution-state emission maximum in MeCN, Φ PL is the photoluminescence quantum yield in deaerated solution, L max is the maximum luminance observed from device, CE is the current efficiency, PE is the power conversion efficiency, t 1/2 is the time taken for the device luminance to fall to half the maximum value, λ EL is the electroluminescence emission maximum