Skip to main content
. 2017 Jan 1;30(3):216–221. doi: 10.1177/1971400916689484

Table 1.

Diagnostic performance results for group A images and group B images in the detection of superior semicircular canal (SSC) dehiscence in 42 patients clinically diagnosed with SSC dehiscence syndrome and in 42 control participants.

Sensitivity Specificity AUC Accuracy TP TN FP FN
Group A images 85.7% 100.0% 0.929 92.9% 36 42 0 6
Group B images 97.6% 100.0% 0.988 98.8% 41 42 0 1

Group A images: reformatted CT images of the temporal bone oriented in the standard transverse and coronal planes.

Group B images: reformatted CT images of the temporal bone oriented in parallel (plane of Pöschl) and perpendicular (plane of Stenver) planes to the SSC.

AUC: area under the receiver operating characteristic curve; TP: true positive, TN: true negative, FP: false positive, FN: false negative; CT: computed tomography.