Skip to main content
. 2017 Jun 19;9(3):217–223. doi: 10.4047/jap.2017.9.3.217

Table 2. Mean values and standard deviation (SD) of physico-mechanical tests.

PC- control SPNC
0% 1.0% 3.0% 5.0%
Setting time (min) Initial 33.6 (1.8)a 31.2 (1.4)a 25.5 (1.2)b 21.2 (0.5)c
Final 67.2 (2.6)A 65.6 (1.9)A 52.3 (1.8)B 45.5 (1.4)C
Compressive strength (MPa) 24 h 32.7 (2.5) 31.2 (1.9) 30.3 (2.4) 30.5 (1.2)
168 h 41.7 (2.4) 39.4 (3.3) 40.9 (2.2) 41.2 (1.4)
Solubility (%) 24 h 0.97 (0.02)a 0.92 (0.05)a 2.02 (0.03)b 2.03 (0.01)b
168 h 1.62 (0.04)A 1.73 (0.06)A 2.73 (0.12)B 2.81 (0.07)B
Silver releases (mg/L) 24 h 0 (0)a 0.011 (0.002)a 0.142 (0.008)b 0.297 (0.02)c
168 h 0 (0)A 0.009 (0.003)A 0.139 (0.011)B 0.272 (0.019)C

Different superscript letters in the same row indicate statistically significant difference (P <.05).

Bold font indicates a statistical significance between 24 h and 168 h intervals (P < .05).