Table 2. Mean values and standard deviation (SD) of physico-mechanical tests.
PC- control | SPNC | ||||
---|---|---|---|---|---|
0% | 1.0% | 3.0% | 5.0% | ||
Setting time (min) | Initial | 33.6 (1.8)a | 31.2 (1.4)a | 25.5 (1.2)b | 21.2 (0.5)c |
Final | 67.2 (2.6)A | 65.6 (1.9)A | 52.3 (1.8)B | 45.5 (1.4)C | |
Compressive strength (MPa) | 24 h | 32.7 (2.5) | 31.2 (1.9) | 30.3 (2.4) | 30.5 (1.2) |
168 h | 41.7 (2.4) | 39.4 (3.3) | 40.9 (2.2) | 41.2 (1.4) | |
Solubility (%) | 24 h | 0.97 (0.02)a | 0.92 (0.05)a | 2.02 (0.03)b | 2.03 (0.01)b |
168 h | 1.62 (0.04)A | 1.73 (0.06)A | 2.73 (0.12)B | 2.81 (0.07)B | |
Silver releases (mg/L) | 24 h | 0 (0)a | 0.011 (0.002)a | 0.142 (0.008)b | 0.297 (0.02)c |
168 h | 0 (0)A | 0.009 (0.003)A | 0.139 (0.011)B | 0.272 (0.019)C |
Different superscript letters in the same row indicate statistically significant difference (P <.05).
Bold font indicates a statistical significance between 24 h and 168 h intervals (P < .05).