Table 2.
Reason for revision | Time from index surgery | Treatment | Outcome |
---|---|---|---|
Infection | 16 y | Two stage revision | Knee doing well at follow-up. ROM 0°-105°. |
Aseptic loosening | 11 y | Revision TKA | 6 y after revision, painless ROM 0°-90° |
Aseptic loosening | 5 y | Revision TKA | Painless ROM 0°-90° at 15 y from revision |
Poly wear | 12 y | Poly exchange | At 8 y after poly exchange, mild knee pain with knee ROM 0°-120°. No evidence of osteolysis |
Poly wear | 12 y | Poly exchange | At 8 years after poly exchange mild knee pain with knee ROM 0°-130°. Mild poly wear lateral compartment, no osteolysis |
Poly, polyethylene; ROM, range of motion.