Skip to main content
. 2017 May 18;7(1):67–72. doi: 10.3892/br.2017.913

Table II.

Diagnostic performance of HE4 in differentiating patients with ovarian cancer from healthy control subjects.

Variable Serum HE4 Urine HE4 R-HE4
Area under the curve 0.955 0.959 0.815
P-value <0.001 <0.001 <0.001
95% CI 0.907–1.004 0.915–1.003 0.705–0.926
Cut-off value 88.65 14116 96.15
Sensitivity (%) 87.1 83.9 71.0
Specificity (%) 100.0 100.0 88.9
Youden's index (%) 87.1 83.9 59.9

HE4, human epididymis protein 4; R-HE4, ratio of urinary-to-serum HE4 level; CI, confidence interval.