Skip to main content
. 2017 Jun 30;7:4455. doi: 10.1038/s41598-017-04510-1

Table 1.

Summary of the mechanical properties of some vascular grafts and native tissues (means ± standard deviations).

Sample Dynamic compliance (% per 100 mmHg) Burst Pressure (mmHg) Suture retention strength (N) Elastic modulus (MPa)
This work 2.46 ± 0.56 >10000 mmHg 6.1 ± 1.7 1.54 ± 0.44
Electrospun SF5 3.51 ± 0.42 575 ± 17
Bilayered SF 2.3 ± 0.5 806 ± 185 5.6 ± 0.9 17.9 ± 3.2
PTFE45 0.2–0.9 2580–8270 2.45–11.77 918 ± 52.930
Saphenous vein45 0.7–2.6 1600–2500 1.76–2.45