Published in final edited form as: Int J Radiat Biol. 2016 Nov 4;93(1):48–57. doi: 10.1080/09553002.2016.1234725

Table I.

Dose assessments (in vitro)* obtained by the analysis of 20 lymphocyte PCC spreads per coded slide by each laboratory group.

Group Actual dose (Gy) Estimated dose (Gy) 95% LCL (Gy) 95%UCL (Gy)
L0 0 0 0 0
0.5 0.48 0.42 0.56
1.0 0.9 0.8 1.0
2.0 1.8 1.6 2.0
3.0 2.7 2.4 3.0
4.0 3.5 3.0 4.0
5.0 4.4 3.9 5.0
6.0 5.1 4.5 5.8
L1 0 0 0 0
0.5 0.62 0.55 0.7
1.0 1.1 1.0 1.3
2.0 1.9 1.7 2.1
3.0 2.8 2.5 3.2
4.0 3.5 3.0 4.1
5.0 4.2 3.7 4.8
6.0 5.1 4.5 5.7
L3 0 0 0 0
0.5 0.2 0.1 0.3
1.0 0.5 0.4 0.6
2.0 1.2 1.1 1.4
3.0 1.7 1.5 1.9
4.0 1.7 1.5 1.9
5.0 2.8 2.5 3.2
6.0 3.6 3.2 4.1
L5 0 0 0 0
0.5 0.58 0.5 0.65
1.0 0.8 0.7 0.9
2.0 1.3 1.1 1.5
3.0 2.1 1.8 2.4
4.0 3.0 2.6 3.4
5.0 3.6 3.1 4.0
6.0 5.3 4.7 5.9
*

The dose estimates were obtained using a calibration curve generated at L0 following the irradiation of human lymphocytes (from 10 donors) to X-rays (200 kV, 4 mA). The dose response curve was found to be linear (α= 4.1 and β= 0.07).