Table V.

Dose estimates obtained by three participating laboratories (L1, L2, and L6) based on dicentric analysis in G0-lymphocyte PCCs, using Centromere-Telomere staining with peptide nucleic acid (PNA) probes, for both samples Re5 (0.85 Gy) and Re6 (2.7 Gy).

Code Whole body dose estimate and 95% confidence limits Participating Laboratory
20 cells 30 cells 50 cells
dose (Gy) LCL UCL dose (Gy) LCL UCL dose (Gy) LCL UCL
Re5a 0.78 0.04 1.96 0.98 0.30 1.89 0.77 0.26 1.46 L1
Re5a 1.8 0.95 2.78 1.5 0.86 2.34 1.5 0.95 2.08 L2
Re5a 0.7 0.5 0.9 0.9 0.7 1.2 1 0.7 1.2 L6
Re5b 1.3 1.1 1.7 1.4 1.1 1.8 1 0.8 1.3 L6
Re6a 3.66 2.72 4.70 3.12 2.36 3.96 3.29 2.70 3.93 L1
Re6a 3.3 2.48 4.29 2.9 2.28 3.74 2.7 2.17 3.29 L2
Re6a 2.4 1.9 2.9 2.3 1.8 2.7 2.3 1.8 2.7 L6
Re6b 2.8 2.2 3.3 2.5 2 3 2.2 1.7 2.6 L6