. 2017 May 12;4(1):e000178. doi: 10.1136/bmjresp-2017-000178
(b) Constant time 0.5 s, P0.5
P0.5 sound parameter Correlation with cough strength VAS
Free-field microphone Contact microphone
PW 0.88 (0.67 to 0.90) 0.83 (0.46 to 0.85)
Ep 0.77 (0.61 to 0.88) 0.68 (0.52 to 0.88)
RT 0.32 (−0.09 to 0.66) 0.44 (−0.02 to 0.71)
D 0.17 (0.00 to 0.31) 0.17 (0.00 to 0.31)
Fp 0.43 (0.21 to 0.65) 0.30 (0.00 to 0.64)
BW 0.03 (−0.62 to 0.32) 0.12 (−0.24 to 0.39)
Fc 0.34 (0.06 to 0.72) 0.66 (0.31 to 0.78)

Data are presented as median (IQR) within-subject Spearman's correlation coefficients between cough sound and cough strength VAS. Individual correlation coefficients are presented in online supplementary table 7. (PW, power; Ep, peak energy; RT, rise time; D, duration; Fp, peak frequency; BW, bandwidth; Fc, centroid frequency).