Skip to main content
. 2017 Jul 10;12(7):e0180124. doi: 10.1371/journal.pone.0180124

Table 2. Development of the microRNA scoring system using the training set.

# Selected
for panel
MicroRNA AUC-ROC p value Youden J
Associated
Criterion Value
95% Confidence
interval
Sensitivity Specificity Sample
size
Positive group Negative group
1 x 148a-3p 1 0.0001 ≤28.04 ≤27.93 to ≤28.04 100 100 11 6 (54.55%) 5 (45.45%)
2 x 301a-3p 0.9 0.0001 ≤25.08 ≤24.64to ≤25.08 100 69.23 20 7 (35.00%) 13 (65.00%)
3 x 671-3p 0.98 0.0001 ≤28.80 ≤28.03 to ≤28.75 100 88.89 14 5 (35.71%) 9 (64.29%)
4 x 181a 0.84 0.0005 ≤25.84 ≤24.61 to ≤26.91 85.71 72.73 18 7 (38.89%) 11 (61.11%)
5 x 210 0.81 0.002 ≤21.04 ≤19.70 to ≤22.19 71.43 84.62 20 7 (35.00%) 13 (65.00%)
6 x 1267 0.79 0.006 ≤14.31 ≤14.15to ≤15.47 85.71 76.92 20 7 (35.00%) 13 (65.00%)
7 x 223 0.77 0.02 ≤12.33 ≤9.95 to ≤12.61 85.71 61.54 20 7 (35.00%) 13 (65.00%)
8 x 340-5p 0.79 0.02 ≤21.31 ≤20.55to ≤23.01 57.14 100 20 7 (35.00%) 13 (65.00%)
9   16 0.76 0.06 ≤13.49 ≤13.12 to ≤15.31 85.71 76.92 20 7 (35.00%) 13 (65.00%)
10   193a-3p 0.75 0.08 ≤26.67 ≤25.00 to ≤29.78 71.43 75 15 7 (46.67%) 8 (53.33%)
11   132 0.73 0.1 ≤24.74 ≤23.25 to ≤29.33 71.43 76.92 20 7 (35.00%) 13 (65.00%)
12   133b 0.73 0.1 ≤23.88 ≤22.85to ≤27.48 71.43 76.92 20 7 (35.00%) 13 (65.00%)
13   30e-3p 0.67 0.19 ≤16.80 ≤16.51 to ≤16.80 100 46.15 20 7 (35.00%) 13 (65.00%)
14   146a 0.68 0.2 ≤17.20 ≤16.37 to ≤18.82 71.43 69.23 20 7 (35.00%) 13 (65.00%)
15   1244 0.66 0.28 ≤23.56 ≤22.84 to ≤26.64 71.43 75 19 7 (36.84%) 12 (63.16%)
16   7-5p 0.64 0.36 >28.47 >25.4 to >30.79 71.43 62.5 15 7 (46.67%) 8 (53.33%)
17   582-5p 0.7 0.4 ≤29.13 ≤27.77 to ≤29.70 80 75 9 5 (55.56%) 4 (44.44%)
18   575 0.67 0.43 ≤27.34 ≤23.94 to ≤27.34 100 66.67 12 6 (50.00%) 6 (50.00%)
19   199b-5p 0.67 0.53 >26.50 >26.06 to >29.70 83.33 66.67 9 6 (66.67%) 3 (33.33%)
20   1229 0.67 0.62 ≤26.75 ≤25.50 to ≤26.75 100 66.67 7 4 (57.14%) 3 (42.86%)
21   155 0.51 0.97 ≤14.13 ≤12.11 to ≤14.62 28.57 46.15 20 7 (35.00%) 13 (65.00%)
22   196a 0.5 1 >23.79 >22.49 to >26.72 100 50 9 5 (55.56%) 4 (44.44%)
23   1 NA NA NA NA NA NA NA NA NA
24   144-3p NA NA NA NA NA NA NA NA NA
25   199a-5p NA NA NA NA NA NA NA NA NA
26   219-5p NA NA NA NA NA NA NA NA NA
27   221-5p NA NA NA NA NA NA NA NA NA
28   33a-5p NA NA NA NA NA NA NA NA NA
29   424-5p NA NA NA NA NA NA NA NA NA
30   513-5p NA NA NA NA NA NA NA NA NA

Using the 20 sample training set, an AUC-ROC was calculated for each of the 30 microRNAs used in the study.

MicroRNA where the p value was less than 0.05 were included in the panel.

“NA” represents microRNA for which an insufficient number of samples signaled to generate a ROC curve.

Eight microRNAs were included in the scoring panel: microRNA 148a, -301a, -671, -181a, -210, -1267, -223, and microRNA -340.

A cutoff value for each of these microRNAs was concurrently determined as the Youden Index J Associated Criterion Value.

Cutoff values for all eight microRNAs were then used to verify the eight-microRNA risk score for individual patients in the validation set.