Published in final edited form as: Ultrasound Med Biol. 2017 Apr 26;43(7):1476–1485. doi: 10.1016/j.ultrasmedbio.2017.03.009

Figure 6.

Figure 6

Effect of reciprocal changes in pulse length and pulse repetition frequency to maintain constant total ultrasound exposure time at constant (free-field) acoustic pressures of 16 MPa peak positive, and −9.9 MPa peak negative at f = 1.95 MHz. Treated volume was 100 μL; total treatment time was 1 minute. Treatments ranged from 5 cycle pules at 2 kHz PRF to 100 cycles at 0.2 kHz PRF. Each point is the mean of four replicate observations within treatment and experiment; error bars represent the experimental standard deviation. The solid line represents the mean of experimental means.