Skip to main content
. Author manuscript; available in PMC: 2017 Jul 10.
Published in final edited form as: Magn Reson Imaging. 2017 Feb 20;39:194–199. doi: 10.1016/j.mri.2017.02.009

Figure 3.

Figure 3

Magnitude (A) and phase (B) imaging of the myelin MBP powder phantom, as well as single-exponential decay fitting of UTE images of myelin basic protein (MBP) powder which shows a short T2* of 172 ± 12 μs (C).