Skip to main content
. Author manuscript; available in PMC: 2017 Jul 11.
Published in final edited form as: J Mol Cell Cardiol. 2016 Apr 13;94:162–175. doi: 10.1016/j.yjmcc.2016.04.003

Table D.1.

Parameters estimated/used for simulating the CVS model

Parameter Description Value Reference
Circulatory Parameters
RPV Pulmonary vasculature resistance 19.2 mmHg sec mL−1 Fixed
RSV Systemic vasculature resistance 117.6 mmHg sec mL−1 Fixed
RAo Aortic resistance 1.96 mmHg sec mL−1 Arbitrarily set
CAo Aortic compliance 0.00015 mL mmHg−1 Arbitrarily set
CSA Systemic artery compliance 0.0035 mL mmHg−1 Fit to CVS data
CSV Systemic vein compliance 19.33 mL mmHg−1 Fixed
CPA Pulmonary artery compliance 2.42 mL mmHg−1 Fit to CVS data
CPV Pulmonary vein compliance 0.009 mL mmHg−1 Fixed
τCO Mean cardiac output time constant 5 sec Fixed
τPA Mean pulmonary artery time constant 30 sec Fixed
τSA Mean systemic artery time constant 30 sec Fixed
TriSeg parameters
Vw,lw LV wall volume 0.4653 mL Determined from experiments
Vw,sw Septal wall volume 0.2506 mL Determined from experiments
Vw,rw RV wall volume 0.1933 mL Determined from experiments
Am,refLW
LV midwall reference surface area 1.38 cm2 Fit to CVS data
Am,refSW
Septal midwall reference surface area 0.78 cm2 Fit to CVS data
Am,refRW
RV midwall reference surface area 2.18 cm2 Fit to CVS data
Other parameters
KSE Stiffness of series element 5000 mmHg μm−1 See text
visc Viscosity coefficient of myofibers 1 mmHg sec μm−1 Fixed