Skip to main content
. 2016 Sep 30;25(5):696–702. doi: 10.1016/j.jsps.2016.09.006

Table 2.

Precision and accuracy of ent-phyllanthidine (FV1) and rutin (FV2).

Marker compound Nominal concentration (a) Concentration obtained ± SD (b) Precision (c) (CV, %) Accuracy (d)
Intraday batch
FV1 200 197.0 ± 3.62 1.84 98.5
400 395.8 ± 5.70 1.44 98.9
600 596.9 ± 7.83 1.31 99.5
FV2 150 147.2 ± 2.37 1.61 98.1
300 296.5 ± 4.11 1.39 98.8
600 597.8 ± 7.43 1.24 99.6



Interday batch
FV1 200 196.6 ± 3.65 1.85 98.3
400 394.8 ± 6.53 1.65 98.7
600 591.3 ± 8.15 1.37 98.5
FV2 150 146.1 ± 2.12 1.45 97.4
300 294.3 ± 5.32 1.80 98.1
600 596.1 ± 10.47 1.75 99.4