Skip to main content
. 2017 Jul 11;12(7):e0180151. doi: 10.1371/journal.pone.0180151

Table 4. Values of axial forces predicted by the microFE models for Et = 12.0GPa and Et = 4.6GPa and experimentally measured, for all specimens.

The absolute percentage differences (%diff_AF) between numerical and experimental values are reported.

Specimen ID AF_Exp [N] Et = 12.0GPa Et = 4.6GPa
AF_microFE [N] %diff_AF AF_microFE [N] %diff_AF
S#1 2953 6881 133% 2643 10%
S#2 1060 1910 80% 734 31%
S#3 1122 5256 369% 2019 80%
S#4 3028 6999 131% 2689 11%