A comprehensive table of design parameters for a five-organ ×10−6 HOC. We propose increasing blood volume levels beyond those called for by conventional quarter-power scaling relationships (QPSRs) to account for engineering limitations in organ design. Chamber dimensions are selected to match in-vivo shear levels (F-2D) or match in-vivo mass (F-3D).

Organ Class ×10−6 HOC
Surface area [mm2] Tissue mass [mg] Blood volume (BV) [μL] % BV % CO Compartment dimension
Length [mm] Width [mm] Height [mm]
Lung Endothelium F-2D 30 0.12 1.1
Non-EC F-2D 40 0.16 1.4
Total F-2D 70 0.28 2.5 4 100 9.02 7.76 0.035
Liver Endothelium F-2D 80 0.32 2 14.87 5.38 0.025
Non-EC F-3D 34 1.75 1.03 1.57 1.57 1
Total F-2/3D 114 2.07 3.03 5 25
Heart F-3D 0.33 0.28 0.5 4 1.06 1.06 0.5
Fat F-3D 12.5 10.7 18 5 4.96 4.96 1
Blood 60
“Other Tissues” F-3D 48.8 43.5 73 66 6.6 6.6 1
Blood Oxygen Content [BLO2; mM] ~2
Cutaneous Respiration [mol/m/s/mmHg] ≤3.8 × 10−11
Cardiac Output [mL/s] 3.4 × 10−3
Intervessel Distance [IVD; μm] 250