Skip to main content
. Author manuscript; available in PMC: 2018 Jul 1.
Published in final edited form as: Brain Stimul. 2017 Apr 10;10(4):757–763. doi: 10.1016/j.brs.2017.04.003

Figure 2.

Figure 2

Overall atDCS effect and reliability across consecutive sessions. A) Combined session average of MEP amplitude (mV) for each time point (Pre, Post0, Post15, Post30) and condition (2mA, 1mA, sham). Two-way ANOVARM was performed with CONDTION and TIME, comparing pre with post-values. Post-hoc pairwise comparisons were performed using Bonferroni correction (*, p≤0.05; **, p≤0.01; ***, p≤0.001). B) Mean MEP amplitudes for each session and condition across time. ICC, calculated with all post-time points from the 3 sessions for each condition (n = 9/condition), showed fair to high reliability. Errors bars represent SEM.