Skip to main content
. 2017 Mar 9;18(1):48–53. doi: 10.14744/AnatolJCardiol.2017.7581

Table 2.

Electrocardiographic and echocardiographic of the study population compared using suitable post-hoc (multiple comparison) tests

Parameters Control group (n=88) HCM group (n=66) P1 value P2 value P3 value
VEA absent (n=40) VEA present (n=26)
Tp-e interval 67.1±13.9 74.6±9.3 82.6±9.8 0.001 <0.001 0.005
QT interval 361±32 379±29 386±39 0.009 0.004 0.799
QTc interval 404±40 416±33 414±34 0.131 0.600 0.813
Tp-e/QTc ratio 0.167±0.03 0.181±0.03 0.202±0.03 0.128 <0.001 0.024
Heart rate 75±11 73±10 70±9 0.657 0.091 0.449
Max LVWT 11.1±1.4 20.2±4.8 22.9±3.5 <0.001 <0.001 0.031
LVEF 64.5±3.5 68.3±3.0 68.4±4.7 <0.001 <0.001 0.992

HC - hypertrophic cardiomyopathy; LVEF - left ventricular ejection fraction; Max LVWT - maximal left ventricular wall thickness; RAS - renin-angiotensin system; QTc - corrected QT; Tp-e - T wave peak to end interval; VEA - ventricular arrhythmic event; P1: Comparison between control group and VEA absent; P2: Comparison between control group and VEA present; P3: Comparison between VEA absent and VEA present