Skip to main content
. 2017 Jun 1;29(3):138–144. doi: 10.1089/acu.2017.1223

Table 1.

Results from the Gee Model, Comparing Mean Change of Tinnitus Based on the VAS and TEOAE, from Baseline in Outcomes Between Patients With and Without Response to Somatic Maneuvers

  Mean (95% CI)  
Test Patients without response Patients with response P-value
VAS
Change immediately after acupuncture −0.2 (−0.45, 0.05) −0.06 (−0.5, 0.39) 0.587
Change 30 minutes after acupuncture −0.3 (−0.58, −0.02) −0.24 (−0.58, 0.11) 0.777
Change 1 day after acupuncture −0.35 (−0.63, −0.07) 0.07 (−0.47, 0.61) 0.175
TEOAE (dBSPL)
Change immediately after acupuncture 2.09 (−0.62, 4.8) 0.02 (−0.65, 0.69) 0.145
Change 30 minutes after acupuncture −4.68 (−12.05, 2.69) 0.25 (−0.3, 0.8) 0.191

GEE, generalized estimating equation; VAS, visual analogue scale; TEOAE, transient-evoked otoacoustic emissions; CI, confidence interval; dBSPL, decibel sound pressure level.