Skip to main content
. Author manuscript; available in PMC: 2018 Jun 1.
Published in final edited form as: IEEE Sens J. 2017 Apr 18;17(11):3526–3541. doi: 10.1109/JSEN.2017.2694965

Fig. 8.

Fig. 8

Response of (FBG 1,2,3) and axial (FBG 4) sensors during two sample loading conditions: (a) pure transverse loading and (b) pure axial loading. Probability distribution of Bragg wavelength shift errors for lateral (c–e) and axial (f) FBG sensors under 168 different combinations of transverse and axial forces. The standard deviations are less than 0.6 pm for the lateral FBGs and is about 1.96 pm for the axial FBG, indicating a highly repeatable response.