Table 2.

Comparison of dynamic CT perfusion to quantiative [15O] H2O PET

Modality Baseline Perfusion (mL/min/g) Hyperemic Perfusion (mL/min/g)
PET 1.00 ± 0.25 3.26 ± 1.04
FPA 1.18 ± 0.58 5.44 ± 1.44
MSM 0.54 ± 0.12 1.82± 0.43