Table 3.
Results of the NIRS-SPM GLM analysis for the assessment of significant functional activity at single task-block level and t-values for each channel and each contrast.
Ch. 1 |
Ch. 2 |
Ch. 3 |
Ch. 4 |
Ch. 5 |
Ch. 6 |
|
---|---|---|---|---|---|---|
Contrasts | t(58) | t(58) | t(58) | t(58) | t(58) | t(58) |
Task#1 vs Rest#1 | 4.99 | 4.80 | 3.41 | 4.45 | 5.21 | 5.26 |
Task#2 vs Rest#2 | 3.29 | 3.51 | 3.03 | 3.39 | 4.57 | 4.19 |
Task#3 vs Rest#3 | 5.38 | 5.60 | 5.24 | 4.44 | 5.77 | 5.65 |
Task#4 vs Rest#4 | 4.52 | 4.94 | 5.14 | 3.74 | 6.01 | 5.11 |
Task#5 vs Rest#5 | 3.85 | 4.70 | 3.86 | 3.56 | 4.87 | 3.89 |
Task#6 vs Rest#6 | 2.89 | 4.29 | 3.67 | 3.39 | 5.86 | 4.20 |
All the contrasts computed on the fNIRS activation signals achieved statistical significance (p<0.008 Bonferroni corrected for multiple comparisons).